Toshiba Air Conditioner Not Heating, What Is Going On
A Toshiba air conditioner not heating on a cold morning can leave the whole house chilly.
Before assuming the worst, it helps to know that heat pumps pause for warm up and defrost, which can look like a fault. This page explains normal heating behaviour, the simple checks to try and the real faults that need a technician.
How does a Toshiba heat pump heat the room?
In heating mode, the refrigerant flows in reverse compared with cooling. The outdoor coil runs colder than the outside air and absorbs heat from it, even on chilly mornings. Next, the compressor raises the temperature of that heat, and the indoor coil releases it into the room. A reversing valve in the outdoor unit switches the system between cooling and heating.
Because the system moves heat rather than creating it from scratch, it heats efficiently. However, it relies on the outdoor coil staying clear of ice and the reversing valve working properly.
What is normal when heating starts?
When you switch to heat mode, the indoor fan usually waits until the indoor coil warms up. That prevents a blast of cold air. The wait can last a minute or several minutes on cold mornings. During this time, the unit may look idle, with lamps lit but no airflow. This is normal.
If heating has not started after ten to fifteen minutes, then something else may be wrong.
Why does heating pause in winter?
On cold, damp days, frost forms on the outdoor coil as it absorbs heat from the air. To clear the frost, the unit runs a defrost cycle. During defrost, the indoor fan slows or stops, the outdoor unit may steam and you might hear a whoosh or click. After a few minutes, heating resumes.
Defrost is normal and necessary. On very cold, humid mornings, it can happen fairly often. It becomes a concern only if it seems constant or the outdoor coil stays heavily iced.
What should you check first with a Toshiba air conditioner not heating?
Try these checks before booking.
- Confirm the remote shows heat mode.
- Set the temperature a few degrees above the room temperature.
- Wait ten to fifteen minutes for warm up and any defrost.
- Clean the indoor filters.
- Look for flashing lamps and read any check code.
- Check that the outdoor unit runs and is not buried in ice.
- Check the breaker and isolator.
Many heating complaints end at one of these steps.
Could the mode or set temperature be wrong?
Yes. If the remote shows cool, dry or fan, the unit will not heat. In auto mode, it may cool if it thinks the room is warm enough. Also, if the set temperature sits below the room temperature, the unit will not heat at all. Choose heat mode and a set point a few degrees above the room.
How do dirty filters affect heating?
Clogged filters restrict airflow across the indoor coil. In heating mode, that means the coil holds its heat rather than delivering it to the room. Pressures and temperatures rise, and the unit may slow the compressor to protect itself, which reduces heating further. Cleaning the filters often makes a clear difference. Our filter guide explains how.
Is heavy ice on the outdoor unit normal?
A thin layer of frost that clears during defrost is normal. Thick ice covering the whole outdoor coil, or ice that never clears, is not. Possible causes include a faulty outdoor coil sensor, a blocked drain under the unit, low refrigerant or an outdoor fan problem. Heavy ice blocks airflow, so heating drops sharply.
If you see heavy ice, switch the unit off and let it melt naturally. Do not chip at it or pour hot water on it. Then book a check. Our page on code 1b explains the outdoor coil sensor that controls defrost.
Could the reversing valve be stuck?
If the unit blows cool air in heat mode, the reversing valve may have stuck in the cooling position. Often, the board notices that the indoor coil is getting colder instead of warmer and shows code 08. A stuck valve or a failed valve coil needs a technician.
What about low refrigerant?
Low refrigerant reduces heating just as it reduces cooling. The unit runs longer, delivers less warmth and may ice up more than usual. Since the refrigerant circuit is a sealed loop, a low charge always means a leak. The technician finds and repairs the leak, then recharges by weight. Our gas regas page explains the process.
Could a sensor be at fault?
Several sensors guide heating. The indoor coil sensor tells the unit when to start the indoor fan, the room sensor tells it when to slow down and the outdoor coil sensor guides defrost. A faulty sensor can delay the fan, end heating too early or upset defrost. Complete sensor failures usually show codes such as 0C, 0d or 18.
Does outdoor temperature matter?
Yes. As outdoor air gets colder, there is less heat to collect, so heat pump output drops. In most of Sydney, winter temperatures stay well within what Toshiba heat pumps handle comfortably. Even so, on the coldest mornings in western or higher suburbs, heating may take longer and defrost may happen more often.
Why does one room stay cold?
On a multi split, if only one room stays cold, check that indoor unit first, including its filters, mode and remote. Remember that indoor units sharing one outdoor unit usually need compatible modes, so if another room runs cool, the cold room may not heat. If every room struggles, the shared outdoor unit is the likely cause.
How can room conditions affect heating?
Heat escapes through windows, gaps under doors and poorly insulated ceilings. In a draughty room, the unit may run constantly yet never feel warm enough. Closing curtains at dusk, keeping doors shut and blocking draughts help a lot. Also, since warm air rises and wall units sit high, pointing the louvres downward helps warm air reach where you sit.
Why does the outdoor unit steam?
During defrost, warm refrigerant flows through the outdoor coil and melts the frost. On cold mornings, that melting frost turns partly into steam, which can look dramatic, almost like smoke. It is harmless and stops within a few minutes. Water then drips from the base of the outdoor unit, which is also normal.
If you ever see steam with a burning smell, or smoke that looks dark, switch the system off at once and call us.
What if the outdoor unit sits in a frost hollow?
Some outdoor units sit in low, shaded spots where cold air settles and water pools. In those places, melt water from defrost can refreeze around the base and the fan. Over time, ice builds up, the drain blocks and the fan may even freeze in place, which can trigger code 1A. Raising the unit on a stand or improving drainage usually solves this.
Does the indoor fan blow cold air at first?
It should not. Toshiba units hold the indoor fan back until the coil warms, specifically to avoid cold drafts. If you feel cold air for more than a moment at start up, the coil sensor that controls this delay may have a fault, or the unit may be in defrost. Mention cold drafts when booking, since they help pinpoint the cause.
Can running costs rise when heating struggles?
Yes. A unit that struggles to heat runs longer and harder, so power use climbs while comfort falls. Heavy icing and frequent defrost also waste energy. Clean filters, a clear outdoor unit and correct refrigerant charge keep heating efficient. If your winter bills have jumped without a change in use, a check may pay for itself.
What about heating in bedrooms overnight?
Overnight heating works best with a moderate set point and a quiet or sleep setting. Very high set points make the unit run hard all night and can dry out the air. A timer that starts heating half an hour before you wake often gives better comfort than running all night. Our timer guide explains how.
Why does the unit heat well some days and not others?
Heating performance depends on outdoor temperature and humidity. On dry, cold days, frost forms slowly and heating runs smoothly. On damp, cold days, frost forms quickly and defrost happens more often, so heating feels patchier. That variation is normal. However, if the unit struggles even on mild days, a fault is more likely.
What does a technician check?
A technician starts with settings, filters and indoor airflow. Then they inspect the outdoor unit for ice, debris and fan operation. After that, they measure pressures and temperatures in heating mode and watch a defrost cycle where possible. They also test sensors and the reversing valve. These checks reveal whether the problem lies with airflow, defrost, refrigerant or a component.
What repairs fix poor heating?
Repairs may include the following.
- Cleaning filters, coils and fans.
- Replacing a faulty outdoor coil sensor to restore proper defrost.
- Clearing drainage under the outdoor unit or raising it to stop ice build up.
- Repairing an outdoor fan.
- Repairing a refrigerant leak and recharging.
- Replacing a reversing valve coil or the valve itself.
- Replacing a board in rarer cases.
The technician explains the cause and price before starting.
Is it worth repairing heating on an older unit?
In most cases, yes. Sensors, fans, drains and even reversing valves can be repaired, and the unit may give many more winters of service. However, if the compressor is failing or the coil has corroded badly, replacement may offer better value. The technician will explain both paths so you can decide.
How long does a heating repair take?
Cleaning and sensor repairs often finish in one visit. Leak and valve repairs take longer because of refrigerant work. The technician gives you a realistic time frame after diagnosis.
How do you keep heating costs under control?
A few habits make winter heating cheaper. First, set a moderate temperature, around twenty degrees, rather than pushing the unit to its maximum. Next, close doors so the unit heats only the rooms you use. Then draw curtains at dusk to keep heat in. Finally, clean the filters every few weeks through winter, since dust builds up quickly when windows stay shut.
Combined, these steps help the unit reach temperature faster and then idle along quietly, which uses far less power than running flat out.
How can you prepare for winter?
Before winter, clean the filters, check the outdoor unit for debris and make sure it sits above pooling water. Run heating once on a mild day to confirm it works. A pre winter service lets a technician check refrigerant, sensors and defrost operation. Our service page explains what a service covers.
What should you share when booking?
Tell us whether the unit blows cold, cool or no air, how long you waited, whether the outdoor unit iced up and whether any lamps flash. Include the model from the indoor unit label.
Who repairs Toshiba air conditioners not heating in Sydney?
We repair Toshiba air conditioners that are not heating across Sydney. To book, phone 02 9071 1142 or use our booking page. The technician will check defrost, sensors, refrigerant and the reversing valve and explain the fix before starting. Many faults leave small clues, such as a smell, a sound or a change in airflow, so share anything you noticed.
Frequently asked questions
Why is my Toshiba not heating straight away?
Toshiba units hold the indoor fan back until the coil warms, which can take a few minutes on cold mornings.
Why does heating stop and start in winter?
The unit pauses to defrost the outdoor coil, which is normal.
Is ice on the outdoor unit normal?
Light frost that clears during defrost is normal. Heavy ice that does not clear is not.
Why does my Toshiba blow cold air in heat mode?
The reversing valve may be stuck, or the unit may be in defrost or the wrong mode.
Can dirty filters reduce heating?
Yes. They restrict airflow and make the unit slow down to protect itself.
How do I book?
Phone 02 9071 1142 with the model, symptoms and any check code.